Western Reserve Controls WRC-CANR-DF Manuale Utente

Navigare online o scaricare Manuale Utente per Gateway/Controller Western Reserve Controls WRC-CANR-DF. Western Reserve Controls WRC-CANR-DF User`s manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - User’s Manual

1782-JDM DeviceNet™-Modbus Gateway User’s Manual Western Reserve Controls, Inc.

Pagina 2

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 6 2.2 How to Change the DeviceNet Baud Rate 1. The baud rate defaults to autobaud.

Pagina 3 - LIST OF TABLES

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 7 Each time a new message is received at the JDM from the Modbus network, it will in

Pagina 4 - LIST OF FIGURES

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 8 3 Hardware Installation and Configuration 3.1 Overview The ASCII contains two L

Pagina 5 - 1 Overview

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 9 Table 3-1 Module Status LED (labeled MS) LED State Module Status Meaning OFF

Pagina 6 - 1.3 JDM Basic Operation

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 10 Table 3-3 Serial Port Connections Pin # RS232 Signal RS485 Signal Designator 1 T

Pagina 7 - 1.3.2 Explicit Messages

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 11 • 1% metal film • 1/4 Watt An appropriate terminating resistor kit, WRC part n

Pagina 8 - 1.5 EDS

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 12 Table 3-6 DeviceNet Conductor Sizes Function Thick Wire Thin Wire Power 15 A

Pagina 9 - 2 Quick Start

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 13 Table 3-7 Configuration Parameters Parameter Param. Instance Description Parame

Pagina 10

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 14 1. Modbus Mode: The JDM can operate in either the ASCII or RTU mode for Modbus co

Pagina 11

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 15 4 DeviceNet I/O Assembly Formats The following tables define the format of the

Pagina 12 - 3.2 LED Operation

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 Although every effort has been made to insure the accuracy of this document, a

Pagina 13 - 3.3 RS232/RS485 Connector

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 16 Table 4-2 I/O Assembly Object Instance 1 Data Format – Response Byte (Offset val

Pagina 14 - 3.5 Network Configuration

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 PRELIMINARY 17 5 General Specifications Product: 1782-JDM – DeviceNet-to-Modbus

Pagina 15

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 18 Phoenix Contact MSTBA 2.5/5-G-5.08/AU or equivalent DeviceNet Cable: 5-conta

Pagina 16 - 3.6 Software Configuration

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 19 6 Accessories and Other WRC Products The following components can be used with a

Pagina 17

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 20 7 Troubleshooting This section identifies some of the common problem observed

Pagina 18

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 i TABLE OF CONTENTS 1 OVERVIEW...

Pagina 19 - value)

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 ii TABLE 3-4 NETWORK MAXIMUM LENGTHS...

Pagina 20

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 PRELIMINARY 1 1 Overview The 1782-JDM is a family of DeviceNet-to-Modbus interface

Pagina 21

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 2 • Operates independently of operation of Modbus device • Forwards the message rece

Pagina 22

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 3 for each message. Therefore, each message to a Modbus device has 2 addresses assoc

Pagina 23

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 4 1.4 Default Device Configuration The JDM DeviceNet address is read from the switc

Pagina 24 - 7 Troubleshooting

Western Reserve Controls 1782-JDM User’s Manual PUB 24.0 5 2 Quick Start To quickly and easily install your JDM in your DeviceNet system,

Commenti su questo manuale